BUS Updated 12/2011
07/2011
2-162
WorkCentre 5335 Family Service Documentation
016-341, 016-342
Initial Issue
Status Indicator RAPs
016-341 ESS FontROM Fail-4 RAP
Slot2 loaded Font ROM CheckSum is out of spec.
Initial Actions
Power Off/On
Procedure
Remove/insert ESS FontROM DIMM. If the problem continues, replace ESS FontROM DIMM
(
PL 35.2
). If the problem persists, replace ESS PWB (
PL 35.2
).
016-342 ESS RTC Failure RAP
RTC time range is out of the specified range. (Ex. 13 month 36 day) Time does not go on.
Initial Actions
Power Off/On
Procedure
If the problem persists, replace ESS PWB (
PL 35.2
).