BUS Updated 12/2011
07/2011
2-972
WorkCentre 5335 Family Service Documentation
124-343, 124-344
Initial Issue
Status Indicator RAPs
124-343 CRUM Market Fail SYS 2 RAP
System Fail. One of CRUM destinations is different from the others (SYS 2). One of the CRUM
destinations stored in three positions does not match (Data stored in the ESS PWB (
PL 35.2
)
does not match).
Procedure
•
(Software available for
Machine ID/Billing Data
)
Enter
Machine ID/Billing Data
. Master SYS2 to resolve the problem. If the problem per-
sists, replace the Cont NVM and the Cont PWB in order.
(Software unavailable for
Machine ID/Billing Data
)
Reload software
GP 16
. If the problem still reoccurs, replace the ESS PWB (
PL 35.2
).
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP
124-344 All Billings Meter Types Mismatch RAP
BSD-ON:
BSD 3.8 - Electronic Billing
System Fail. Billing Meter Type Fail (All the three are different from each other.) All the billing
meter types kept at multiple locations are different.
Procedure
Power OFF then ON. If the problem persists, perform the following:
Reload software
GP 16
. Replace the MCU PWB (
PL 18.2
) and the ESS PWB (
PL 35.2
).