![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_8843081099.webp)
BUS Updated 12/2011
07/2011
4-38
WorkCentre 5335 Family Service Documentation
REP 6.2
Initial Issue
Repairs & Adjustments
9.
Remove the ROS Cover (
Figure 8
).
a.
Remove the Screws (2) on the left side of the cover.
b.
Remove the top Screw (1).
c.
Move the cover to the left and remove it.
Figure 8 Removing Screws
10. Disconnect the ROS PJ’s (4) and release the wire harness from the clamps (
Figure 9
).
Figure 9 PJ’s
CAUTION
Do not touch the ROS window when holding it.
NOTE: The ROS screws are longer then the other screws, keep them with the ROS for rein-
stallation.
11.
Remove the ROS (
Figure 10
).
a.
Remove the Screws (5).
b.
Remove the ROS.
Figure 10 Removing Screws
Replacement
NOTE: When reinstalling the ROS be sure to seat the ROS into the two locating holes in the
machine frame.
1.
To install, carry out the removal steps in reverse order.
a
b
c
10
a