WorkCentre 5335 Family Service Documentation
016-348, 016-350
Initial Issue
Status Indicator RAPs
016-348 ESS PageMemory Failure-2 RAP
W/R/V test error for Page Memory.
Initial Actions
Power Off/On
Procedure
Remove/insert System Memory. If the problem continues, replace ESS PWB (
PL 35.2
).
016-350 ESS EEPROM DIAG Failure 1 RAP
BSD-ON:
BSD 16.1 - ESS
Product ID cannot be obtained.
Initial Actions
Power Off/On.
Procedure
1.
Check connections between the following components:
•
ESS EEPROM and ESS PWB (check for bent pins etc.) (
PL 35.2
).
2.
Check the sw version of the controller sw - update if required
3.
If problem persists replace ESS PWB.
PL 35.2
.