WorkCentre 5335 Family Service Documentation
012-211 (Integrated Finisher)
Initial Issue
Status Indicator RAPs
Y
N
Check the connections of
P/J8707
and
P/J8722
.
P/J8707
and
P/J8722
are securely
connected.
Y
N
Connect
P/J8707
and
P/J8722
securely.
Check for an open or short circuit between
P/J8707
and
P/J8722
. The wires between
P/J8707
and
P/J8722
are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB
P/J8707
-6 (+) and GND (-). The voltage is
approx. +5VDC.
Y
N
Go to
Integrated Finisher Wirenets
and check the +5VDC circuit.
Measure the voltage between Finisher PWB
P/J8707
-5 (+) and (-). Block and unblock the
Stacker Stack Sensor 1 by rotating the actuator. The voltage changes.
Y
N
Replace the Stacker Stack Sensor 1 (
PL 22.8
).
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB (
PL 22.7
).
Enter [012-279]. Block and unblock the Stacker Stack Sensor 2 by rotating the actuator. The
display changes.
Y
N
Check the connections of
P/J8707
and
P/J8721
.
P/J8707
and
P/J8721
are securely
connected.
Y
N
Connect
P/J8707
and
P/J8721
securely.
Check for an open or short circuit between
P/J8707
and
P/J8721
. The wires between
P/J8707
and
P/J8721
are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB
P/J8707
-3 (+) and GND (-). The voltage is
approx. +5VDC.
Y
N
Go to
Integrated Finisher Wirenets
and check the +5VDC circuit.
Measure the voltage between Finisher PWB
P/J8707
-2 (+) and GND (-). Block and
unblock the Stacker Stack Sensor 2 by rotating the actuator. The voltage changes.
Y
N
Replace the Stacker Stack Sensor 2 (
PL 22.8
).
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB (
PL 22.7
).
Enter [012-060] and [012-061] alternately. The Stacker Motor rotates.
Y
N
Check the connections of
P/J8711
and
P/J8736
.
P/J8711
and
P/J8736
are securely
connected.
Y
N
Connect
P/J8711
and
P/J8736
securely.
Check for an open or short circuit between
P/J8711
and P8736. The wires between
P/
J8711
and P8736 are OK.
Y
N
Repair the open or short circuit.
Enter [012-060], measure the voltage between Finisher PWB
P/J8711
-1 (+) and GND (-
). The voltage changes.
Y
N
Go to
Integrated Finisher Wirenets
and check the +24VDC circuit. If the problem
continues, replace the Finisher PWB (
PL 22.7
).
Enter [012-061], measure the voltage between Finisher PWB
P/J8711
-2 (+) and GND (-
). The voltage changes.
Y
N
Go to
Integrated Finisher Wirenets
and check the +24VDC circuit. If the problem
continues, replace the Finisher PWB (
PL 22.7
).
Check the wires and connectors for an intermittent open and short circuit. If the problem
continues, replace the Stacker Motor (
PL 22.8
).
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB (
PL 22.7
).