BUS Updated 12/2011
07/2011
2-856
WorkCentre 5335 Family Service Documentation
116-329, 116-330
Initial Issue
Status Indicator RAPs
116-329 Serial Software RAP
A system call error related to the Serial I/F was detected.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)
116-330 HDD File System RAP
The HDD Check detected an error during power on or the HDD is not formatted.
Initial Actions
Power Off/On
Procedure
•
Check the HDD electrical connections (
PL 35.2
).
•
Check the sw version of the controller sw - update if required
•
If the problem persists perform
Hard Disk Failure Prediction Test
.
Perform
GP 14
- only the first 3 parts - make sure to follow sequence and heed cautions
CAUTION
All customer data on the HDD (customer’s files/configuration such as mailboxes, scanned
documents, user IDs and account IDs for accounting) will be deleted.
1.
Job Log Clear Mode
2.
HDD Initialize Mode
3.
HDD Format Mode
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)