BUS Updated 12/2011
07/2011
2-370
WorkCentre 5335 Family Service Documentation
021-525, 021-528
Initial Issue
Status Indicator RAPs
021-525 Inconsistency of Withdrawal Status RAP
Withdrawal is requested but withdrawn status is detected internally. When starting withdrawal
processing, System Data "Installation status" indicates "Not installed".
Procedure
Power OFF/ON. If the problem persists, perform the procedures:
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM)
021-528 Communication Setting Error RAP
At the start of communication, communication-disabling setting is detected. At the start of com-
munication, System Data "Installation status" indicates "Not installed".
Procedure
Power OFF/ON. If the problem persists, perform the procedures:
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM)