![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308300.webp)
BUS Updated 12/2011
07/2011
2-287
WorkCentre 5335 Family Service Documentation
016-985
Status Indicator RAPs
Initial Issue
016-985 Data Size Over Flow (Scan to E-mail) RAP
Data Size Over Flow (Scan to E-mail). It was not possible to send during a scan to e-mail
because the data size exceeded the upper bound.
Procedure
1.
Reduce resolution (image quality for transmission), which is a send parameter, and
resend.
2.
Reduce reduce/enlarge ratio, which is a send parameter, and resend. (E.g. Reduce A3 to
A4.)
3.
Change ‘Upper limit of data size’ in the System Setting screen on UI Panel. (Default 2MB
recommended)
4.
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
5.
Check the sw version of the controller sw - update if required (
GP 16
)