![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_8843081441.webp)
BUS Updated 12/2011
07/2011
6-46
WorkCentre 5335 Family Service Documentation
GP 11
Initial Issue
General Procedures & Information
850-013
Scan-Ahead Func-
tion
Enable/Disable Scan-Ahead Feature with FDI-CRD.
This function is not effective if [850-030] = 0.
0 = Disable Scan-Ahead (default)
1:Enable Scan-Ahead
NOTE: Setting of 1 is recommended on any Subtractive Device to
avoid free side-2 copy/print with CRD.
850-014
FDI Connect Wait
Time
Amount of time for MC to wait for FDI-CRD to boot-up after MC is power
ON. If MC did not detect FDI-CRD within time, the system declares a fault
(121-333).
0 = Wait for 10 seconds (default)
1 - 9 = Number of minutes to wait before fault is declared.
850-015
Scan/Fax/Internet
Fax Job Control
Disable / Enable controlling charge on Scan/Fax/Internet Fax jobs at storing
and sending in Fax/Internet Fax jobs.
Valid only when charge type is Xerox Card, JIS II Card or IC Card. (Multiple
connection of CRD devices with the above the charge types)
0 = disabled (default)
1 = enabled
850-016
Operational when
Job-in-Process is
disabled and Sub-
tractive Mode CRD
is connected
NOTE: This function is only available in FX/FX-IBG Market.
Change system behavior based on Subtractive CRD or CRD set to Sub-
tractive Mode, and Job-in-Process is disabled.
0 = All Xerox Europe
1 = Cancel
2 = Pause automatically clear remaining jobs
850-017
Use of card num-
ber upon Print Job
Control
Disable / Enable charging Print Jobs to Card Number when the card were
inserted.
NOTE: Valid only when Print Job Control [850-009] is enabled.
0 = disabled (default)
1 = enabled
850-018
Paper Transfer in
Duplex Mode
Disable/Enable single-sheet feed mode during Duplex Printing, when Sub-
tractive CRD is connected.
0 = Regular Speed
1 = Single-Sheet Feed Mode (default)
NOTE: Setting of 1 is recommended on any Subtractive Device to
avoid free side-2 copy/print with CRD.
850-030
Copy Job Control
Disable / Enable controlling charge copy jobs by FDI-CRD
0 = disabled (default)
1 = enabled
700-125
Job Cancel Timer
Amount of time (unit = seconds) until Paused Job is cancelled
Table 1 FDI NVM Settings
NVM loc.
Name
Function
Values