BUS Updated 12/2011
07/2011
2-867
WorkCentre 5335 Family Service Documentation
116-355, 116-356
Status Indicator RAPs
Initial Issue
116-355 Agent Software RAP
An internal shutdown occurred after an SNMP (Simple Network Management Protocol) pro-
cessing error.
Initial Actions
Power Off/On
Procedure
•
Change the system data 700-530 to "0" and disable the automatic startup boot operation
at SystemFail (make sure to reset to 1 when complete
•
Check the sw version of the controller sw - update if required
•
Remove and re-install or replace the System Memory and Page Memory DIMMs (
PL
35.2
).
•
Specially check for faulty ports or Net connection. Check which of the following ports is
faulty.
–
SNTP
–
NetWare
–
Salutation IO
–
SMB
–
Port 9100
–
USB
–
lpd
–
FTP Serv
–
MailIO
–
IPP
–
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)
116-356 HDD Format RAP
The M/C was not started up due to an insufficient HDD capacity error detected during HDD for-
matting.
Initial Actions
Power Off/On
Procedure
•
Check the HDD electrical connections (
PL 35.2
).
•
Check the sw version of the controller sw - update if required
•
If the problem persists perform
Hard Disk Failure Prediction Test
.
Perform
GP 14
- only the first 3 parts - make sure to follow sequence and heed cautions
CAUTION
All customer data on the HDD (customer’s files/configuration such as mailboxes, scanned
documents, user IDs and account IDs for accounting) will be deleted.
1.
Job Log Clear Mode
2.
HDD Initialize Mode
3.
HDD Format Mode
•
Replace HDD (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)