WorkCentre 5335 Family Service Documentation
021-215, 021-360
Status Indicator RAPs
Initial Issue
021-215 Invalid Accessory Type RAP
The setting for accessory type, NVM location 850-007, does not mkatch the type of accessory
installed must be set to 0.
Procedure
NOTE: IF FDI is removed from the IOT, NVM 850-007 must be set to 0.
Change the value in NVM location 850-007 to the appropriate one for the connected acces-
sory, then power OFF then ON. Or replace the connected accessory with the appropriate one
for the setting, then power OFF then ON.
021-360 Accessory Fail RAP
BSD-ON:
BSD 3.7 - ESS-FDI Communication
An error occurred in the connection to the foreign accessory. The accessory that should be
installed is not found.
Procedure
Turn the power OFF then ON.
1.
Check the connection to the accessory, pull out and insert the FDI and replace the cable.
2.
If the problem persists, replace the FDI.
3.
If the trouble persists, replace the ESS PWB (
PL 35.2
).
4.
Check that the Controller software is the latest version.