BUS Updated 12/2011
07/2011
4-194
WorkCentre 5335 Family Service Documentation
ADJ 5.4
Initial Issue
Repairs & Adjustments
ADJ 5.4 DADF Lead Edge Registration
Parts List on
PL 1.4
Purpose
To adjust the original to the proper position (original feed direction) on the Platen.
NOTE: The following adjustments must be made before carrying out checking and adjustment.
•
IOT Lead Edge/Side Edge Registration (
ADJ 9.10
)
•
IIT Lead Edge Registration (
ADJ 6.3
)
•
IIT Side Edge Registration (
ADJ 6.4
)
•
DADF Lead-Skew Adjustment (
ADJ 5.1
)
Check
1.
Place the 82E8220 Test Pattern on the Document glass with the trade mark and part
number as the lead edge.
2.
Set up the machine to make two sided copies of the test pattern as follows:
a.
On the UI Ready to Copy Screen, select the Copy tab.
b.
Under Output Color select Black.
c.
Under the Paper Supply select 11x17” paper size.
d.
Under 2 Sided Copying select 1 to 2 Sided.
e.
Reduce / Enlarge should be set to 100%.
f.
On the UI Ready to Copy Screen, select the Layout Adjustment tab, Image Shift
should be Side 1 and Side 2 No Shift. Select Save.
3.
Select a Quantity of 5.
4.
Press the Start button to make a copy of side 1.
5.
After side 1 is made, place a small piece of paper with the words side 2 written on it, onto
the Document Glass and under the 82E8220 Test Pattern.
NOTE: Side 2 can now be identified by the word “side 2” copied from the small piece of
paper placed on the Document Glass under the test pattern from previous step.
6.
Press the Start button to make a copy of side 2.
NOTE: The 2 sided copies will be used to run duplex sets for measurement through the
DADF.
7.
Place the 2 sided copies into the DADF and make one set of 2 sided copies.
8.
On side 1 and side 2, measure on the scale from the 10 MM. line to the edge of the paper.
The measurement should as follows. (
Table 1
)
If the value is not within the specified range, perform the Adjustment:
Figure 1 Identifying side 2
9.
If the value is not within the specified range, perform the Adjustment:
Table 1 Specification
Item
Simplex
Duplex
Lead Edge
10
±
0.5mm
10
±
0.5mm
Piece of paper to
identify side 2
The 10 MM. line is located
on this scale