BUS Updated 12/2011
07/2011
2-138
WorkCentre 5335 Family Service Documentation
013-213
Initial Issue
Status Indicator RAPs
013-213 Booklet Staple Move Position Sensor Off Fail RAP
(LX)
BSD-ON:
BSD 12.25 - Office Finisher Booklet Staple Positioning
Booklet Staple Move Position Sensor does not turn off within designated time period
Initial Actions
•
Ensure the Staple Head is free from obstructions
•
Check for 013-306 or 013-307 Faults.
Procedure
Execute
Component Control
[013-144], Booklet Staple Move Position Sensor. Move the Book-
let Stapler to block and unblock the sensor (
PL 23.18
). The display changes.
Y
N
Check the wire between
J8898
pin 2 and
P/J8991
pin 5; and the wire between
J8984
,
pin 5 and
J8895
pin 5 for an open or short circuit, or a loose or damaged connector.
The wires are OK.
Y
N
Repair/reconnect as required.
Measure the voltage between
P/J8991
, pins 6 and 4 on the Booklet PWB. The voltage
is approx. +5VDC.
Y
N
Replace the Booklet PWB (
PL 23.21
).
Measure the voltage between
P/J8991
pin 5 on the Booklet PWB and GND. Actuate the
Booklet Staple Move Position Sensor. The voltage changes.
Y
N
Replace the Booklet Staple Move Position Sensor (
PL 23.18
).
Measure the voltage between
J8895
pin 5 on the Finisher PWB and GND. Actuate the
Booklet Staple Move Position Sensor. The voltage changes.
Y
N
Replace the Booklet PWB (
PL 23.21
). If the problem persists, replace the Finisher
PWB (
PL 23.16
).
Replace the Finisher PWB (
PL 23.16
).
Alternately execute
Component Control
[013-028], Stapler Move Motor In and [013-029], Sta-
pler Move Motor Out. The Stapler Move Motor moves.
Y
N
Check the wires between
P/J8992
pins 1~6 on the Booklet PWB and
P/J8906
on the
Booklet Stapler Move Motor for an open or short circuit, or loose or damaged connectors.
The wires are OK.
Y
N
Repair/replace as required.
Monitor the voltage at
J8984
, pin 3. Alternately execute
Component Control
[013-028],
Stapler Move Motor In and [013-029], Stapler Move Motor Out. An AC clock pulse is
detected.
Y
N
Check the wire between
J8984
, pin 3 and
J8895
pin 4. If the wire is OK, replace the
Finisher PWB (
PL 23.16
).
Replace the Booklet Stapler Move Motor (
PL 23.18
). If the problem persists, replace the
Booklet PWB (
PL 23.21
).
Go to
BSD 12.25 - Office Finisher Booklet Staple Positioning
and check for an intermittent
circuit.
A
A
B