BUS Updated 12/2011
07/2011
2-424
WorkCentre 5335 Family Service Documentation
024-976, 024-977
Initial Issue
Status Indicator RAPs
024-976 Staple Status Failed RAP
BSD-ON:
BSD 12.21 - Office Finisher LX Staple Control
•
After the Stapler Motor turned On (Forward rotation), the system did not detect that the
Staple Head Home Sensor switched from Off to On within the specified time.
•
After the Stapler Motor turned On (Reverse rotation), the Staple Head Home Sensor did
not turn On within the specified time.
Initial Actions
•
Power Off/On
Procedure
•
Go to the
012-291
Stapler Failure RAP
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 16
)
024-977 Stapler Feed Ready RAP
BSD-ON:
BSD 12.21 - Office Finisher LX Staple Control
Procedure
•
Go to
012-291
(Office Finisher LX).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 16
)