BUS Updated 12/2011
07/2011
2-155
WorkCentre 5335 Family Service Documentation
016-322, 016-323
Status Indicator RAPs
Initial Issue
016-322 JBA Account Full RAP
BSD-ON:
BSD 16.1 - ESS
The accumulated accounting data in Job Based Accounting reached the specified value.
Procedure
•
Switch the power off then on 2 minutes after the job is attempted (after an external
Accounting Server has read the accounting data).
•
If the problem persists, have the customer perform a manual retrieval of machine data
from their Accounting server.
•
If the problem persists, perform
Initialize Hard Disk
and then have the customer push the
User Accounts to the machine from their Accounting server.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM.)
016-323 B Formatting RAP
BSD-ON:
BSD 34.1 - FAX
An internal formatting error occurred. Unrecoverable error is detected within Fax Send image
conversion area B-Formatter task from extended mailbox in "Multi-Send using Job Flow Indica-
tion" or "UI Multi-Send".
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM.)