BUS Updated 12/2011
07/2011
2-977
WorkCentre 5335 Family Service Documentation
124-353, 124-360
Status Indicator RAPs
Initial Issue
124-353 CRUM OEM Fail SYS 2 RAP
System Fail. One of CRUM OEM destinations is different from the others (SYS 2). One of the
CRUM OEM destinations stored in three positions does not match (Data stored in the ESS
PWB (
PL 35.2
) does not match).
Procedure
•
(Software available for
Machine ID/Billing Data
)
Enter
Machine ID/Billing Data
. Meter SYS2 to resolve the problem. If the problem per-
sists, replace the Cont NVM and the Cont PWB in order.
(Software unavailable for
Machine ID/Billing Data
)
Reload software
GP 16
. If the problem still persists, replace the ESS PWB (
PL 35.2
).
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP
124-360 CRUM Validation Fail All RAP
System Fail. All three CRUM Enable/Disable settings are not set (0 or different values are set).
The CRUM Enable/Disable settings stored in three positions match but their values are not set
(0).
Procedure
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP
•
Reload software
GP 16
. Replace the machine, or replace the MCU Board (
PL 18.2
).