BUS Updated 12/2011
07/2011
2-210
WorkCentre 5335 Family Service Documentation
016-567, 016-568
Initial Issue
Status Indicator RAPs
016-567 NVM Backup Capacity Full RAP
The backup destination has insufficient capacity.
Procedure
•
Before performing the HDD backup, delete existing backup files through the panel to
increase the capacity.
•
Before performing USB backup, delete the backup files in the USB memory through the
panel, or use a PC to delete unnecessary files in the USB memory to increase the capac-
ity.
016-568 NVM Backup Restore Failed RAP
BSD-ON:
BSD 16.1 - ESS
One of the following problems has occurred:
•
NVM data could not be backed up or restored for some reason
•
An HDD access error has occurred.
•
A USB Memory access error has occurred.
•
The backup file was corrupted during restore.
Procedure
•
Format the HDD before performing HDD backup.
•
Before performing restore using the HDD backup file, delete backup files through the
panel. If the problem persists, format the HDD.
•
For USB backup, check that the USB Memory is properly installed. If the problem per-
sists, use a PC to format the USB Memory.
•
When performing restore using USB backup files, check that the USB Memory is properly
installed. If the problem persists, use the panel or a PC to delete the backup files.
•
If the problem still persists, use a PC to format the USB Memory.