![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308298.webp)
BUS Updated 12/2011
07/2011
2-285
WorkCentre 5335 Family Service Documentation
016-949, 016-981
Status Indicator RAPs
Initial Issue
016-949 Insert Mix Doc NG RAP
The document with a different size/orientation from the operated page was tried to be
inserted for the job with Attachment specified.
Procedure
•
Specify the job to avoid the detection conditions.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 16
)
016-981 HDD Access Failure RAP
BSD-ON:
BSD 34.1 - FAX
A failure in access to HDD
HDD Full was detected because Mailbox Scan, Fax Scan, Secure Print, Delay Print,
Sample Print, or Scheduled Print was specified when the HDD partition/ide0c capacity is
small.
–
Print Job only prints the jobs stored in the HD, so this Fault does not occur for "Job
Fail 16-748".
Procedure
1.
Split the job into pages in order to prevent FULL state. Reduce the resolution if possible.
2.
Delete documents that are no longer needed, such as: Mailbox documents, FAX Send
Wait documents, Secure Print documents and Delayed Print documents. Make sure that
there is space in the HDD before re-scanning and re-printing.