BUS Updated 12/2011
07/2011
4-89
WorkCentre 5335 Family Service Documentation
REP 10.7, REP 10.8
Repairs & Adjustments
Initial Issue
5.
Exit Gate Solenoid removal (
Figure 3
).
a.
Disconnect the connector (1).
b.
Remove the Screws (2), and the solenoid.
Figure 3 Removing Screws
Replacement
1.
To install, carry out the removal steps in reverse order.
REP 10.8 Left Hand Chute Interlock Switch
Parts List on PL 17.4
Removal
1.
Switch off the power and disconnect the power cord.
2.
Remove the Exit 2 Assembly
REP 10.5
.
3.
Remove the screws (6) and the Exit 2 Guide Assembly (
Figure 1
).
NOTE: The Exit 2 Guide Assembly Screws have a different thread than the other screws,
keep them with the guide for re-installation.
Figure 1 Removing Screws
4.
Left Hand Chute Interlock Switch removal; disconnect the connector, and release the sen-
sor from the assembly (
Figure 2
).
Figure 2 Removal
Replacement
1.
To install, carry out the removal steps in reverse order.
a
b
3