Status Indicator RAPs
092-656 ATC Average Fail RAP
BSD-ON:
BSD 9.3 - Development and Toner Dispense Control
The average measured value of ATC Sensor is out of the range of appropriate values. (This is
a hidden failure. Data is only recorded in history.)
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The connection between the MCU PWB
P/J413
and the Xero/Developer Cartridge
P/
J615
for open circuit, short circuit, and poor contact
•
The Toner Dispense Motor for revolution failure:
Component Control
[093-002] (
PL 8.2
)
•
The Toner Cartridge for internal toner blockage
If no problems are found, replace the following parts in sequence:
•
Drum Cartridge (
PL 8.1
)
•
MCU PWB (
PL 18.2
)
092-660 ATC Amplitude Fail RAP
BSD-ON:
BSD 9.3 - Development and Toner Dispense Control
The difference between the maximum and minimum values in the ATC Sensor measurement
set is lower than the threshold value. (This is a hidden failure. Data is only recorded in history.)
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The connection between the MCU PWB
P/J413
and the Xero/Developer Cartridge
P/
J615
for open circuit, short circuit, and poor contact
•
The Toner Dispense Motor for revolution failure:
Component Control
[093-002] (
PL 8.2
)
•
The Toner Cartridge for internal toner blockage
If no problems are found, replace the following parts in sequence:
•
Drum Cartridge (
PL 8.1
)
•
MCU PWB (
PL 18.2
)