BUS Updated 12/2011
07/2011
2-784
WorkCentre 5335 Family Service Documentation
062-396, 062-397
Initial Issue
Status Indicator RAPs
062-396 CCD Cable Connection Fail RAP
BSD-ON:
BSD 3.3 - ESS-IIT Communication
A CCD Flat Cable connection error was detected.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
1.
Turn the power OFF and ON.
2.
Turn the power OFF and check the following:
•
Check the Flat Cable between the CCD Lens Assembly
P/J700
and the IIT PWB
P/
J710
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
The coaxial cable between the IIT PWB
P/J7191
and the ESS PWB
P/J336
for
open circuit, short circuit, and poor contact
If no problems are found, replace the following parts in sequence:
•
Reload the machine software (
GP 16
).
•
IIT PWB (Switch the EEPROM) (
PL 1.6
)
•
ESS PWB (
PL 35.2
)
062-397 IIT-Cont Video Cable Connection Fail RAP
BSD-ON:
BSD 3.3 - ESS-IIT Communication
An ESS Video Cable connection error was detected.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
1.
Turn the power OFF and ON.
2.
Turn the power OFF and check the coaxial cable between the IIT PWB
P/J7191
and the
ESS PWB
P/J336
for open circuit, short circuit, and poor contact.
If no problems are found, replace the following parts in sequence:
•
Reload the machine software (
GP 16
).
•
ESS PWB (
PL 35.2
)
•
IIT PWB (Switch the EEPROM) (
PL 1.6
)