BUS Updated 12/2011
07/2011
2-167
WorkCentre 5335 Family Service Documentation
016-365, 016-366
Status Indicator RAPs
Initial Issue
016-365 Cont USB2.0 Device Fail RAP
BSD-ON:
BSD 16.1 - ESS
Cont USB2.0 Device Diagnostic Fail. An error occurred during W/R/V test of PCI Config inter-
val or W/R/V test of internal register.
Procedure
Turn the power OFF then ON. If the problem persists, replace the ESS PWB (
PL 35.2
). Check
the sw version of the controller sw - update if required.
016-366 Cont HDD Fail-1 RAP
BSD-ON:
BSD 16.1 - ESS
Cont HDD Diagnostic Fail-1. An error has occurred during IDE Controller check (ideDrv equiv-
alent)
Procedure
Turn the power OFF then ON. If the problem persists, perform the following:
•
Disconnect and re-connect the HDD Wire Harness (
PL 35.2
).
•
Check for 5VDC between
P/J302
-1 (red) and
P/J302
-3 (blk) on the HDD.
•
Check the sw version of the controller sw - update if required
•
Replace the HDD and the HDD Wire Harness (
PL 35.2
).
•
Replace the ESS PWB (
PL 35.2
).