Status Indicator RAPs
003-757 400dpi Cannot be Scanned RAP
BSD-ON:
BSD 3.5 - ESS-DADF Communication
This status code is displayed if over 400dpi cannot be scanned (DADF). 400/600dpi disabled
for DADF Mix Duplex Mode Scan.
Procedure
•
Perform scan with 300dpi or lower resolution or change the job to that scannable with
NON-MIX mode.
•
If powering OFF then ON does not resolve the problem, perform the following:
1.
Check the cable between IIT PWB and ESS PWB (
PL 35.2
), MCU all PWBs con-
nected to them (RAM, Firmware module, EEPROM).
2.
Check the sw version of the controller sw - reload Software (
GP 16
)
3.
Replace IIT PWB (Switch the EEPROM) (
PL 1.6
)
4.
Replace ESS PWB (
PL 35.2
).
003-760 Scan Settings RAP
BSD-ON:
BSD 3.5 - ESS-DADF Communication
The job properties are incorrect.
Procedure
•
Abort the job. Change Job Startup parameters such as Tray No., Paper size etc. and retry.
•
Disconnect then reconnect the IIT, ESS, MCU all PWBs connected to them (RAM, Firm-
ware module, EEPROM)
•
Check the sw version of the controller sw - reload Software (
GP 16
)
•
Replace IIT PWB (Switch the EEPROM) (
PL 1.6
)