![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_8843081416.webp)
BUS Updated 12/2011
07/2011
6-20
WorkCentre 5335 Family Service Documentation
Component Control
Initial Issue
General Procedures & Information
077-071
Duplex Drive Motor
Drives Duplex Drive Motor with 2 phase excitation. max. speed. (Pull-in direction)
078-003
HCF Feed Motor: Feed
Drives the Motor in the Feed direction at a frequency of 2320PPS (307.5mm/s).
078-004
078-004
HCF Feed Motor: Lift
Drives the Motor in the Lift direction at a frequency of 3395PPS (450mm/s).
Drives it only when HCF Tray Level Sensor is Off.
Stops driving it if the sensor turns On while it is driving.
Does not drive it when HCF Tray In Sensor is Off.
078-003
078-093
HCF T/A Motor
Drives HCF T/A Roll at a speed of 330 mm/s.
091-001
BCR AC Bias
Enable the output of BCR AC Bias
-
091-003,004,005
091-002
BCR DC Bias
Enable the output of BCR DC Bias
-
091-003,004,005
091-003
BCR AC/DC Bias
Simultaneous output of BCR AC Bias, BCR DC Bias
-
091-001, 002,004,005
091-004
BCR AC/DC Bias + Dev.
DC Bias
Simultaneous output of BCR AC Bias, BCR DC Bias and Dev. DC Bias
-
091-001, 002,003,005; 093-001
091-005
BCR AC/DC Bias + Dev.
DC Bias + Drum Motor
Simultaneous output of BCR AC Bias, BCR DC Bias, Dev. DC Bias, and Drum Motor On
-
091-001, 002,003,004; 093-001;
042-001, 002
093-001
Dev. DC Bias
Dev DC output Output value: NVM (Deve-DC I/O Check output value)
-
091-004, 091-005
093-002
Dispense Motor
Output of Dispense Motor
-
094-001
BTR (-)
Outputs the BTR Bias (-).
-
094-002
094-002
BTR (+)
Outputs the BTR Bias (+).
-
094-001
094-003
DTS
Outputs the Detack Bias
-
Table 2 Output Component Control List - IOT/IIT/DADF/HCF
Chain-
Link
Component Description
Time-out conflicts