BUS Updated 12/2011
07/2011
2-974
WorkCentre 5335 Family Service Documentation
124-347, 124-348
Initial Issue
Status Indicator RAPs
124-347 Billing Count Type Restoration Fail RAP
BSD-ON:
BSD 3.8 - Electronic Billing
System Fail. Billing Count Type Fail (One mismatches the others but cannot be automatically
repaired.) When one billing count type did not match, this machine tried to automatically cor-
rect it but failed.
Procedure
Power OFF then ON. If the problem persists, perform the following:
In
NVM Read/Write
compare the values in the following NVMs:
If the values in both 720-052 and 720-063 are the same, replace the MCU PWB (
PL
18.2
).
If they are different, replace the ESS PWB. Reload software
GP 16
.
124-348 All Modal Break Points Mismatch RAP
BSD-ON:
BSD 3.8 - Electronic Billing
System Fail. Modal Break Point Fail (All the three are different from each other.) All the Modal
Break Points kept at multiple locations are different.
Procedure
Power OFF then ON. If the problem persists, perform the following:
Reload software
GP 16
. Replace the MCU PWB (
PL 18.2
) and the ESS PWB (
PL 35.2
).