![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308105.webp)
BUS Updated 12/2011
07/2011
2-91
WorkCentre 5335 Family Service Documentation
012-161 (Integrated Finisher), 012-211 (Integrated
Status Indicator RAPs
Initial Issue
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB (
PL 22.7
).
Enter [012-054] and [012-056] alternately. The Eject Motor rotates.
Y
N
Check the connections of
P/J8706
and
P/J8741
.
P/J8706
and
P/J8741
are securely
connected.
Y
N
Connect
P/J8706
and
P/J8741
securely.
Check for an open or short circuit between
P/J8706
and
P/J8741
. The wires between
P/J8706
and
P/J8741
are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB
P/J8706
-13 (+) and GND (-), and between
P/J8706
-15 (+) and GND (-). The voltage is approx. +24VDC.
Y
N
Go to
Integrated Finisher Wirenets
and check the +24VDC circuit.
Check the Eject Motor drive mechanism for deformed parts, broken parts, and/or belt
damage The drive mechanism free from defects.
Y
N
Repair defects or damage to the drive mechanism.
Replace the Eject Motor (
PL 22.9
). If the problem continues, replace the Finisher PWB
(
PL 22.7
).
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB (
PL 22.7
).
012-211 (Integrated Finisher) Stacker Tray Fail RAP
BSD-ON:
BSD 12.8 - Integrated Finisher Stacker Tray Control
•
Within a specified time after the Stacker Tray started lifting up, the Stack Height Sensor
did not detect the lifting up of the Stacker Tray.
•
Within a specified time after the Stacker Tray started going down at initialization and dur-
ing a job, the lower position of the tray (Full) could not be detected based on the changes
in the Stacker Stack Sensor 1 and the Stacker Stack Sensor 2.
Initial Actions
•
Check the Stack Height Sensor is properly installed, not broken, and has no foreign
object.
•
Check the Stacker Stack Sensors 1 and 2 are properly installed and have no foreign
objects and that their actuators are not broken.
•
Power Off/On.
Procedure
Check the drive mechanism to the Stacker Tray for a deformed or broken part and not-seated
gears. The mechanism is free from defects and the gears seat properly.
Y
N
Repair the mechanism.
Enter
Component Control
[012-267]. Block and unblock the Stack Height Sensor with a piece
of paper. The display changes.
Y
N
Check the connections of
P/J8708
and
P/J8727
.
P/J8708
and
P/J8727
are securely
connected.
Y
N
Connect
P/J8708
and
P/J8727
securely.
Check for an open or short circuit between
P/J8708
and
P/J8727
. The wire between
P/J8708
and
P/J8727
are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB
P/J8708
-3 (+) and GND (-). The voltage is
approx. +5VDC.
Y
N
Go to
Integrated Finisher Wirenets
and check the +5VDC circuit.
Measure the voltage between Finisher PWB
P/J8708
-2 (+) and GND (-). Block and
unblock the Stack Height Sensor with a piece of paper. The voltage changes.
Y
N
Replace the Stack Height Sensor (
PL 22.10
).
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB (
PL 22.7
).
Enter [012-278]. Block and unblock the Stacker Stack Sensor 1 by rotating the actuator. The
display changes.
A