WorkCentre 5335 Family Service Documentation
016-774 , 016-775
Initial Issue
Status Indicator RAPs
016-774 HD Full - Compression Convert RAP
HDD Full at Compression type conversion. HDD Full occurred when the S-Formatter did the
compression type conversion of the JBIG compressed images into the MH system (partition
#1). Disk Full was detected when opening/writing file for Compression type conversion
Initial Actions
Power Off/On
Procedure
•
Free up some HDD space and repeat the operation.
If the problem persists, perform the following procedure to repair it.
–
Disconnect/reconnect HDD
–
Check the sw version of the controller sw - update if required (
GP 16
)
–
Perform
GP 14
- only the first two parts - make sure to follow sequence and heed
cautions
1.
Job Log Clear Mode
2.
HDD Initialize Mode
–
Replace HDD (
PL 35.2
)
–
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB and
RAM DIMM.)
016-775 HD Full - Image Convert RAP
Insufficient HDD capacity was detected during image conversion process by S-Formatter. Disk
Full was detected when opening/writing file for image processing operation.
Initial Actions
Power Off/On
Procedure
•
Free up some HDD space and repeat the operation.
•
Retrieve each page from the EWS.
•
If the problem persists, perform the following procedure to repair it.
–
Disconnect/reconnect HDD
–
Check the sw version of the controller sw - update if required (
GP 16
)
–
Perform
GP 14
- only the first two parts - make sure to follow sequence and heed
cautions
1.
Job Log Clear Mode
2.
HDD Initialize Mode
–
Replace HDD (
PL 35.2
)
–
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB and
RAM DIMM.)