BUS Updated 12/2011
07/2011
2-121
WorkCentre 5335 Family Service Documentation
012-282, 012-283
Status Indicator RAPs
Initial Issue
Go to
BSD 12.22 - Office Finisher LX Eject Control (1 of 2)
. Check for an intermittent circuit
or intermittent mechanical problem. If the check is OK, replace the Finisher PWB (
PL 23.16
).
012-283 Set Clamp Home Sensor On Failure RAP (LX)
BSD-ON:
BSD 12.22 - Office Finisher LX Eject Control (1 of 2)
BSD-ON:
BSD 12.23 - Office Finisher LX Eject Control (2 of 2)
After the Set Clamp started, the Set Clamp Home Sensor did not turn On within 200ms.
Initial Actions
•
Manually operate the Eject mechanism. Check for binding, a dirty sensor, or damage.
•
Check the actuator for the Set Clamp Home Sensor for damage
Procedure
Execute
Component Control
[012-251], Set Clamp Home Sensor. Actuate the Set Clamp
Home Sensor. The display changes.
Y
N
Check the wire between
J8871
pin 2 on the Set Clamp Home Sensor and
P/J8988
pin 11
on the Finisher PWB for an open or short circuit, or loose or damaged connectors. The
wire is OK.
Y
N
Repair/replace as required.
Measure the voltage between
P/J8988
, pins 12 and 10 on the Finisher PWB. The volt-
age is approx. +5VDC.
Y
N
Replace the Finisher PWB (
PL 23.16
).
Measure the voltage between the
P/J8988
pin 11 on the Finisher PWB and GND). Actu-
ate the Eject Clamp Home Sensor. The voltage changes.
Y
N
Replace the Eject Clamp Home Sensor (
PL 23.11
).
Replace the Finisher PWB (
PL 23.16
).
Alternately execute
Component Control
[012-052], Eject Clamp Up and [012-053], Eject Clamp
Down. The Eject Motor starts.
Y
N
Check the wires between
P/J8878
pins 1~6 on the Eject Motor and
P/J8983
pins 5~8 on
the Finisher PWB for an open or short circuit, or loose or damaged connectors
BSD 12.22
- Office Finisher LX Eject Control (1 of 2)
). The wires are OK.
Y
N
Repair/replace as required.
Measure the resistance of the Eject Motor between each pin of
P/J8878
-1/3/4/6. The
resistance is approx. 2 Ohm.
Y
N
Replace the Eject Motor (
PL 23.11
).
Replace the Finisher PWB (
PL 23.16
). If the problem remains, replace the Eject Motor
(
PL 23.11
)
A