BUS Updated 12/2011
07/2011
2-406
WorkCentre 5335 Family Service Documentation
024-900, 024-910
Initial Issue
Status Indicator RAPs
024-900 Upper Tray Out Of Place
A tray above the paper tray selected was "out of place" so it was decided that paper feed was
impossible. This fault occurs depending on the configuration of the paper transport in the
engine.(This occurs only with Front C Path Engine.)
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI. Load the correct paper in the tray. Ensure that all Trays are closed.
024-910 Tray 1 Size Mismatch RAP
BSD-ON:
BSD 7.1 - Tray 1 Paper Size Sensing
BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Operation Error. Size Mismatch Tray 1: Measured Length Mismatch. When the paper slow
scan direction length is measured on the paper path, the length is different from the slow scan
length for the size detected by the tray.
Procedure
•
Load the correct paper in the tray.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
The Tray 1 Paper Size Switch for failure:
Analog Monitor
[071-200];
Component Control
[071-104] (
PL 9.1
)
•
The connection between the Tray 1 Paper Size Sensor
P/J122
and the MCU PWB
P/
J414
for open circuit, short circuit, and poor contact
•
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
•
Reload the machine software (
GP 16
).
•
Replace MCU PWB (
PL 18.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS & MCU)