![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308039.webp)
BUS Updated 12/2011
07/2011
2-23
WorkCentre 5335 Family Service Documentation
003-311 , 003-318
Status Indicator RAPs
Initial Issue
003-311 IIT CDI Interface Mismatch RAP
BSD-ON:
BSD 3.3 - ESS-IIT Communication
BSD-ON:
BSD 16.1 - ESS
Error detected when information sent to controller from IIT via IIT CDI I/F during initialization of
controller is insufficient. (e.g. bad combination of controller SW and IIT SW)
Procedure
•
Reload correct Controller and IIT Software (
GP 16
).
•
Replace IIT PWB (Switch the EEPROM) (
PL 1.6
)
•
Replace the ESS PWB (
PL 35.2
)
003-318 IIT Software RAP
BSD-ON:
BSD 3.3 - ESS-IIT Communication
BSD-ON:
BSD 16.1 - ESS
The IIT software is corrupt.
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
•
Check the sw version of the controller sw
•
Reload Software (
GP 16
)
•
Replace IIT PWB (Switch the EEPROM) (
PL 1.6
)
•
If the problem persists, replace the ESS PWB (
PL 35.2
). (If not fixed by this, reinstall the
original ESS PWB and RAM DIMM.)