BUS Updated 12/2011
07/2011
2-53
WorkCentre 5335 Family Service Documentation
003-955, 003-956
Status Indicator RAPs
Initial Issue
003-955 Documents Size Exchange RAP
Document size change error (MixMode). When loading a document with Mixed Size Originals
prohibited, a document of different size/orientation from the initial document was detected.
Only Image Overlay has the function that inhibits different sizes during document added.
Initial Actions
Check the document size/orientation and repeat the operation.
Procedure
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - reload Software (
GP 16
)
•
Replace the DADF PWB (
PL 51.2
).
•
If the problem persists, replace the IIT PWB (Switch the EEPROM) (
PL 1.6
).mm
003-956 Document Size Unknown Error RAP
Document size undefined error (Only APS is selected for the function requiring document size
setting). Undefined document size was detected when Platen is selected and only APS
requires document size selection.
Procedure
1.
Enter a document size from the Panel or select a tray.
2.
If powering OFF then ON does not resolve the problem, perform the following:
3.
Check the connection between the IIT PWB and ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
4.
Check the sw version of the controller sw - reload Software (
GP 16
)
5.
DADF APS Sensors 1-3:
Component Control
[005-218/219/220] (
PL 51.17
)
6.
Replace IIT PWB (Switch the EEPROM) (
PL 1.6
).
7.
Replace ESS PWB (
PL 35.2
).