![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308793.webp)
BUS Updated 12/2011
07/2011
2-791
WorkCentre 5335 Family Service Documentation
072-212, 072-900
Status Indicator RAPs
Initial Issue
072-212 Tray 2 Paper Size Sensor Broken RAP
BSD-ON:
BSD 7.2 - Tray 2 Paper Size Sensing
Abnormal output AD value from Tray 2 Size Sensor was detected.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
Broken link and breakage at the bottom of the tray
•
The Actuator at the rear of the Tray for operation failure
•
The Tray 2 Paper Size Switch for failure:
Analog Monitor
[072-200];
Component Control
[072-104] (
PL 9.1
)
•
The connection between the Tray 2 Paper Size Sensor
P/J123
and the MCU PWB
P/
J414
for open circuit, short circuit, and poor contact
Reload the machine software (
GP 16
). If no problems are found, replace the MCU PWB (
PL
18.2
).
072-900 Tray 2 Feed Out Sensor Static Jam RAP
BSD-ON:
BSD 8.2 - IOT Paper Transportation
When the power was turned ON, the M/C was stopped (Cycle Down/ Shut Down), or when the
interlocks were closed (all interlocks including options), the Tray 2 Feed Out Sensor detected
paper.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Feed Out Sensor (
PL 15.1
) for remaining paper, contamination, Actuator return fail-
ure, or improper installation
•
The Feed Out Sensor for failure:
Component Control
[072-100] (
PL 15.1
)
•
The connection between the Feed Out Sensor
P/J110
-1 and the MCU PWB
P/J410
-B3
for short circuit
Reload the machine software (
GP 16
). If no problems are found, replace the MCU PWB (
PL
18.2
).