![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308773.webp)
BUS Updated 12/2011
07/2011
2-769
WorkCentre 5335 Family Service Documentation
047-218, 047-320
Status Indicator RAPs
Initial Issue
047-218 Tray Module Communication Fail RAP
BSD-ON:
BSD 3.2 - -MCU-Tray Module Communication
Communication error between Tray Module PWB and MCU PWB was detected.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
1.
Turn the power OFF and ON.
2.
Turn the power OFF. Go to the
BSD 3.2 - -MCU-Tray Module Communication
. Check the
connection between the MCU PWB
P423
and the Tray Module PWB
P/J541
for open cir-
cuit, short circuit, and poor contact.
If no problems are found, replace the following parts in sequence:
•
Reload the machine software (
GP 16
).
•
Tray Module PWB (
PL 11.13
)
•
MCU PWB (
PL 18.2
)
047-320 ALL Destination Tray Broken RAP
All Trays connected to the IOT have become unusable.
Procedure
Enter
Shutdown History
. Go to the RAP of the affected Output Tray.