Rev. 2.0, 11/00, page 768 of 1037
(2) PB-CTL Waveform Shaper in Slow Mode Operation
If bit 0 in the CTL control register (CTCR) is set to slow mode, slow reset function is
activated. In slow mode, if the falling edge is not detected within the specified time from
rising edge detection, PB-CTL is forcibly shut down (slow reset).
The time T
FS
(s) until the signal falls is the following interval after the rising edge of the
internal CTL signal is detected:
T
FS
= 16384
×
4
φ
s
(
φ
s = f
OSC
/2)
When f
OSC
= 10 MHz, T
FS
= 13.1 ms.
Figure 28.54 shows the PB-CTL waveform in slow mode.
CTL waveform
Internal CTL signal
1 frame
1 frame
1 frame
Slow tracking delay
Slow tracking delay
Slow tracking delay
Accelera-
tion
Accelera-
tion
Accelera-
tion
Decelera-
tion
Decelera-
tion
Slow reset
Stop
Stop
CTLP
CTLP
CTLP
Figure 28.54 PB-CTL Waveform in Slow Mode Operation
Summary of Contents for Hitachi H8S/2191
Page 123: ...Rev 2 0 11 00 page 96 of 1037...
Page 149: ...Rev 2 0 11 00 page 122 of 1037...
Page 197: ...Rev 2 0 11 00 page 170 of 1037...
Page 247: ...Rev 2 0 11 00 page 220 of 1037...
Page 249: ...Rev 2 0 11 00 page 222 of 1037...
Page 347: ...Rev 2 0 11 00 page 320 of 1037...
Page 357: ...Rev 2 0 11 00 page 330 of 1037...
Page 417: ...Rev 2 0 11 00 page 390 of 1037...
Page 431: ...Rev 2 0 11 00 page 404 of 1037...
Page 439: ...Rev 2 0 11 00 page 412 of 1037...
Page 457: ...Rev 2 0 11 00 page 430 of 1037...
Page 525: ...Rev 2 0 11 00 page 498 of 1037...
Page 543: ...Rev 2 0 11 00 page 516 of 1037...
Page 845: ...Rev 2 0 11 00 page 818 of 1037...