Rev. 2.0, 11/00, page 490 of 1037
(c) Serial Data Reception (Clock Synchronous Mode)
Figure 23.18 shows a sample flowchart for serial reception.
The following procedure should be used for serial data reception.
When changing the operating mode from asynchronous to synchronous, be sure to check
that the ORER, PER, and FER flags are all cleared to 0.
The RDRF flag will not be set if the FER or PER flag is set to 1, and neither transmit nor
receive operations will be possible.