![Siemens SINAMICS S Series Скачать руководство пользователя страница 999](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427999.webp)
List of parameters
Parameters
1-999
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the number of the encoder that the second channel (control, Motor Module) uses for safe motion monitoring
functions.
Dependency:
For the safe motion monitoring functions, the redundant safety position actual value sensing must be activated in
the appropriate encoder data set (p0430.19 = 1).
Refer to: p0187, p0188, p0189, p0430
Note:
For p9526 = 1, the encoder for the closed-loop speed control is used for the second channel of the motion monitor-
ing functions (1-encoder system).
A change only becomes effective after a POWER ON.
Description:
Sets the tolerance for the function "Safe Operating Stop" (SOS).
Dependency:
Refer to: C01707
Note:
A change only becomes effective after a POWER ON.
SOS: Safe Operating Stop / SBH: Safe operating stop
Description:
Sets the tolerance for the function "Safe Operating Stop" (SOS).
Dependency:
Refer to: C01707
Note:
A change only becomes effective after a POWER ON.
SOS: Safe Operating Stop / SBH: Safe operating stop
Description:
Sets the limit values for the function "Safely-Limited Speed" (SLS).
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
p9526
SI motion encoder assignment second channel / SI Mtn enc chan 2
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1 3
1
p9530
SI motion standstill tolerance (Control Unit) / SI Mtn standst_tol
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [mm]
100.000 [mm]
1.000 [mm]
p9530
SI motion standstill tolerance (Control Unit) / SI Mtn standst_tol
SERVO (Safety rot),
VECTOR (Safety rot)
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [°]
100.000 [°]
1.000 [°]
p9531[0...3]
SI motion SLS (SG) limit values (Control Unit) / SI Mtn SLS lim CU
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [mm/min]
1000000.00 [mm/min]
2000.00 [mm/min]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...