List of parameters
Parameters
1-1049
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the time to carry out the forced checking procedure (test stop).
Within the parameterized time, the digital inputs/outputs must must have been subject to a forced checking proce-
dure at least once. The forced checking procedure is started with BI: p10007 = 0/1 signal.
Dependency:
Refer to: p10001, p10007, p10046
Description:
Displays the actual checksum of the checksum-checked parameters for the Terminal Module 54F (TM54F).
Description:
Displays the reference checksum of the checksum-checked parameters for the Terminal Module 54F (TM54F).
Description:
Select a safety-relevant digital input for the signal "acknowledge internal event" (internal fault).
The signal is transferred to the corresponding control signal of all drives. The falling edge at this input resets the
status "internal event" in the drives.
Values:
0:
Statically active
1:
F-DI 0 (X521.2/3/6)
2:
F-DI 1 (X521.4/5/7)
3:
F-DI 2 (X522.1/2/7)
4:
F-DI 3 (X522.3/4/8)
5:
F-DI 4 (X522.5/6/9)
6:
F-DI 5 (X531.2/3/6)
7:
F-DI 6 (X531.4/5/7)
8:
F-DI 7 (X532.1/2/7)
9:
F-DI 8 (X532.3/4/8)
10:
F-DI 9 (X532.5/6/9)
255:
Statically inact
p10003
SI forced checking procedure timer / SI FrcdCkProcTimer
TM54F_MA
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2848
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [h]
8760.00 [h]
8.00 [h]
r10004[0...1]
SI actual checksum TM54F parameters / SI act CRC TM54F
TM54F_MA,
TM54F_SL
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2846
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p10005[0...1]
SI reference checksum TM54F parameters / SI ref CRC TM54F
TM54F_MA,
TM54F_SL
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2846
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p10006
SI acknowledgement internal event input terminal / SI ackn int event
TM54F_MA,
TM54F_SL
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 255
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...