Parameters
List of parameters
1-958
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the sampling time for the cyclic interface 2 (IF2).
Description:
Connector output for interconnecting the PZD (setpoints) received via interface 2 in the word format.
p8840
COMM BOARD monitoring time / CB t_monit
CU_S (COMM
BOARD, PROFINET)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
65535000 [ms]
20 [ms]
p8841[0...39]
COMM BOARD send configuration data / CB S_config_data
CU_S (COMM
BOARD, PROFINET)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 65535
0
p8842
COMM BOARD start configuration / CB config start
CU_S (COMM
BOARD, PROFINET)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p8848
IF2 PZD sampling time / IF2 PZD t_sample
CU_CX32, CU_S
Can be changed:
C1(3)
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1.00 [ms]
16.00 [ms]
4.00 [ms]
r8849[0...139]
COMM BOARD receive configuration data / CB E_config_data
CU_S (COMM
BOARD, PROFINET)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r8850[0...4]
CO: IF2 PZD receive word / IF2 PZD recv word
A_INF, B_INF,
S_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
2491
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...