Parameters
List of parameters
1-1030
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the changes of the safety message buffer. This counter is incremented every time that the safety message
buffer changes.
Recommend.:
This is used to check whether the safety message buffer has been read-out consistently.
Dependency:
Refer to: r9747, r9748, r9749, p9752, r9753, r9754, r9755, r9756, p9759
Description:
Displays the numbers of safety messages that have occurred.
Dependency:
Refer to: r9744, r9748, r9749, p9752, r9753, r9754, r9755, r9756, p9759
Note:
The messages type "safety message" (Cxxxxx) are entered in the message fault buffer.
Description:
Displays the relative system runtime in milliseconds when the safety message occurred.
Dependency:
Refer to: r9744, r9747, r9749, p9752, r9753, r9754, r9755, r9756, p9759
Description:
Displays the additional information about the safety message that occurred (as integer number).
Dependency:
Refer to: r9744, r9747, r9748, p9752, r9753, r9754, r9755, r9756, p9759
r9744
SI message buffer changes, counter / SI msg_buffer chng
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r9747[0...63]
SI message code / SI msg_code
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r9748[0...63]
SI message time received in milliseconds / SI t_msg recv ms
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r9749[0...63]
SI message value / SI msg_value
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer32
Dynamic index:
-
Func. diagram:
-
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...