List of parameters
Parameters
1-443
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the limit for the torque-generating current component using the stall calculation, the current limit of the
Motor Module as well as the parameterization in p0640.
Index:
[0] = Upper limit
[1] = Lower limit
Description:
Displays the instantaneous stall power.
Dependency:
Refer to: p0326
Description:
For a positive edge, the actual torque (r0079[0]) at this instant in time is used instead of the torque offset from
p1532 as long as p1550 remains at 1.
Description:
For a positive edge, the actual force (r0079[0]) at this instant in time is used instead of the force offset from p1532
as long as p1550 remains at 1.
r1548[0...1]
CO: Stall current limit torque-generating maximum / Isq_max stall
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
6_2
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r1549
CO: Stall power actual value / P_stall
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
14_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [kW]
- [kW]
- [kW]
p1550[0...n]
BI: Transfer actual torque as torque offset / Accept act torque
SERVO
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
9718.23
p1550[0...n]
BI: Transfer actual force as force offset / Accept act force
SERVO (Lin)
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
9718.23
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...