![Siemens SINAMICS S Series Скачать руководство пользователя страница 312](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427312.webp)
Parameters
List of parameters
1-312
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
For vector control (p1300 = 20 ... 23) the maximum speed is limited to 60.0 / (8.333 * p0115[0] * r0313). This can be
identified by a reduction in r1084. p1082 is not changed in this process due to the fact that the operating mode
p1300 can be changed over.
Description:
Sets the maximum speed for the positive direction.
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description:
Sets the maximum velocity for the positive direction.
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description:
Displays the effective positive speed limit.
Dependency:
Refer to: p1082, p1083, p1085
Description:
Displays the effective positive velocity limit.
Dependency:
Refer to: p1082, p1083, p1085
p1083[0...n]
CO: Speed limit in positive direction of rotation / n_limit pos
SERVO, VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3050
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [RPM]
210000.000 [RPM]
210000.000 [RPM]
p1083[0...n]
CO: Velocity limit positive direction / v_limit pos
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3050
P-Group:
Setpoints
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [m/min]
1000.000 [m/min]
1000.000 [m/min]
r1084
Speed limit positive effective / n_limit pos eff
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
3050, 5030,
5210, 6640, 7020, 8010
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
r1084
Velocity limit positive effective / v_limit pos eff
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
3050, 5030,
5210, 6640, 7020, 8010
P-Group:
Setpoints
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...