Description:
Sets the gain when executing the motion-based pole position identification.
Description:
Sets the gain when executing the motion-based pole position identification.
Description:
Sets the integral time when executing the motion-based pole position identification.
Description:
Sets the smoothing time when executing the motion-based pole position identification.
Description:
Sets the scaling for the runtime of the automatic encoder calibration and
the current-impressing technique for the pole position identification routine.
Dependency:
Refer to: p0341, p0342
Caution:
For P1999 > 100% (setting, large moments of inertia) :
There is no locked rotor monitoring (A7970.2).
The plausibility check of the encoder signal (A7970.4) only checks the sign.
p1995[0...n]
Pole position identification gain, motion-based / PolID kp mot_bas
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor identification
Units group:
17_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [Nms/rad]
999999.000 [Nms/rad]
0.300 [Nms/rad]
p1995[0...n]
Pole position identification gain, motion-based / PolID kp mot_bas
SERVO (Lin)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor identification
Units group:
24_2
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [Ns/m]
999999.000 [Ns/m]
10.000 [Ns/m]
p1996[0...n]
Pole position identification, integral time motion-based / PolID Tn mot_bas
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1.0 [ms]
500.0 [ms]
2.0 [ms]
p1997[0...n]
Pole position identification, smoothing time motion-based / PolID t_sm mot_bas
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.0 [ms]
50.0 [ms]
0.0 [ms]
p1999[0...n]
Ang. commutation offset calibr. and pole position ID - scaling / ComOffsCalib scal
VECTOR (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
10 [%]
5000 [%]
100 [%]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...