List of parameters
Parameters
1-973
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
Refer to: p8899
Description:
Setting to invert the individual binector outputs of the connector-binector converter.
Using p8898[0], the signals of CI: p8899[0] are influenced.
Using p8898[1], the signals of CI: p8899[1] are influenced.
Dependency:
Refer to: r8894, r8895, p8899
Description:
Sets the signal source for the connector-binector converter.
A PZD receive word can be selected as signal source. The signals are available to be serially passed-on (intercon-
nection).
Dependency:
Refer to: r8894, r8895
Note:
From the signal source set via the connector input, the corresponding lower 16 bits are converted.
p8899[0...1] together with r8894.0...15 and r8895.0...15 forms two connector-binector converters:
Connector input p8899[0] to binector output in r8894.0...15
Connector input p8899[1] to binector output in r8895.0...15
09
Bit 9
On
Off
-
10
Bit 10
On
Off
-
11
Bit 11
On
Off
-
12
Bit 12
On
Off
-
13
Bit 13
On
Off
-
14
Bit 14
On
Off
-
15
Bit 15
On
Off
-
p8898[0...1]
IF2 invert connector-binector converter binector output / Con/bin outp inv
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
2485, 2491
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Bit 0
Inverted
Not inverted
-
01
Bit 1
Inverted
Not inverted
-
02
Bit 2
Inverted
Not inverted
-
03
Bit 3
Inverted
Not inverted
-
04
Bit 4
Inverted
Not inverted
-
05
Bit 5
Inverted
Not inverted
-
06
Bit 6
Inverted
Not inverted
-
07
Bit 7
Inverted
Not inverted
-
08
Bit 8
Inverted
Not inverted
-
09
Bit 9
Inverted
Not inverted
-
10
Bit 10
Inverted
Not inverted
-
11
Bit 11
Inverted
Not inverted
-
12
Bit 12
Inverted
Not inverted
-
13
Bit 13
Inverted
Not inverted
-
14
Bit 14
Inverted
Not inverted
-
15
Bit 15
Inverted
Not inverted
-
p8899[0...1]
CI: IF2 connector-binector converter signal source / Con/bin S_src
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Integer16
Dynamic index:
-
Func. diagram:
2485, 2491
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...