List of parameters
Parameters
1-739
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
Refer to: p3704, p3705
Description:
Sets the numerator natural frequency for filter 3.2 (general 2nd Order filter) for APC (Advanced Positioning Control).
Dependency:
Refer to: p3704, p3705
Description:
Sets the numerator damping for filter 3.2 (general 2nd Order filter) for APC (Advanced Positioning Control).
Dependency:
Refer to: p3704, p3705
Description:
Sets the proportional gain of the load speed controller 1 for APC (Advanced Positioning Control).
The gain acts on the difference between the speed setpoint and load speed in the branch for filter 2.1 and 2.2.
Description:
Sets the proportional gain of the load velocity controller 1 for APC (Advanced Positioning Control).
The gain acts on the difference between the velocity setpoint and load velocity in the branch for filter 2.1 and 2.2.
Description:
Sets the rate time of the load speed controller 1 for APC (Advanced Positioning Control).
The rate time acts on the load acceleration in the branch for filter 2.1 and 2.2.
p3738[0...n]
APC filter 3.2 numerator natural frequency / APC Filt 3.2 fn_n
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.5 [Hz]
16000.0 [Hz]
2000.0 [Hz]
p3739[0...n]
APC filter 3.2 numerator damping / APC Filt 3.2 D_n
SERVO (APC)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000 10.000
0.700
p3760[0...n]
APC load speed controller 1 P gain / APC n_load ctr1 Kp
SERVO (APC)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-100.000 100.000
0.000
p3760[0...n]
APC load velocity controller 1 P gain / APC v_load ctr1 Kp
SERVO (APC, Lin)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-100.000 100.000
0.000
p3761[0...n]
APC load speed controller 1 rate time / APC n_load ctr1 Tv
SERVO (APC)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7012
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-500.00 [ms]
500.00 [ms]
0.00 [ms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...