![Siemens SINAMICS S Series Скачать руководство пользователя страница 185](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427185.webp)
List of parameters
Parameters
1-185
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Contains the encoder configuration supported by the Sensor Module.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p0404
Note:
ZM: Zero mark
This parameter is only used for diagnostics.
A value of zero is displayed if an encoder is not present.
Description:
Sets the Sensor Module configuration.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
r0456[0...2]
Encoder configuration supported / Enc config supp
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Linear encoder
Yes
No
-
01
Abs value encoder
Yes
No
-
02
Multiturn encoder
Yes
No
-
03
Track A/B sq-wave
Yes
No
-
04
Track A/B sinus
Yes
No
-
05
Track C/D
Yes
No
-
06
Hall sensor
Yes
No
-
08
EnDat encoder
Yes
No
-
09
SSI encoder
Yes
No
-
12
Equidistant zero mark
Yes
No
-
13
Irregular zero mark
Yes
No
-
14
Distance-coded zero mark
Yes
No
-
15
Commutation with zero mark
Yes
No
-
16
Acceleration
Yes
No
-
20
Voltage level 5 V
Yes
No
-
21
Voltage level 24 V
Yes
No
-
22
Remote sense (only SMC30)
Yes
No
-
23
Resolver excit.
Yes
No
-
r0458[0...2]
Sensor Module properties / SM properties
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
4704
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Encoder data available
Yes
No
-
01
Motor data available
Yes
No
-
02
KTY84 connection available
Yes
No
-
03
PTC connection available
Yes
No
-
04
Module temperature available
Yes
No
-
05
Absolute encoder p0408/p0421, no power
of 2
Yes
No
-
06
Sensor Module permits parking/unparking
Yes
No
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...