Parameters
List of parameters
1-762
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice:
The following restrictions apply to this function:
- it is not permissible to change over the drive data set.
- the encoder/drive may not be parked using a PROFIBUS telegram.
- a maximum of 4 drives may be connected to the Control Unit.
- it is not permissible to commutate with the zero mark (p0404).
Note:
Re bit 00:
All of the help functions for long stator motors can be enabled/disabled using this bit.
Re bit 01:
When the bit is set, bit 14 (parking encoder active) is set to 0 in the encoder status word GX_ZSW independent of
whether the encoder is parked or not.
Description:
Sets the signal source to set the commutation angle from CI: p3872.
Dependency:
Refer to: p3870, p3872, p3873, p3874, r3875, p3876, p3878, p3879
Danger:
If an incorrect commutation angle is set, this can result in instability in the closed-loop control and in turn injure per-
sonnel or cause damage to the machine !
Note:
Setting takes place for a 0/1 signal edge.
Description:
Sets the signal source for the commutation angle.
This angle is set for a 0/1 signal edge via BI: p3871.
Dependency:
Refer to: p3870, p3871, p3873, r3875, p3876, p3878, p3879
Danger:
If an incorrect commutation angle is set, this can result in instability in the closed-loop control and in turn injure per-
sonnel or cause damage to the machine !
Description:
Sets the signal source to change over to closed-loop control with encoder.
Dependency:
Refer to: p3870, p3871, p3872, p3874, r3875, p3876, p3878, p3879
Danger:
If an incorrect commutation angle is set, this can result in instability in the closed-loop control and in turn injure per-
sonnel or cause damage to the machine !
p3871
BI: Set long stator signal source commutation angle (p3872) / Set S_src com_ang
SERVO
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p3872
CI: Long stator signal source commutation angle / S_src com_angle
SERVO
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
3878[0]
p3873
BI: Long stator sig. source changeover to cl.-loop ctrl w/ enc. / S_src ctrl w/ enc
SERVO
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
-
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...