![Siemens SINAMICS S Series Скачать руководство пользователя страница 1044](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271044.webp)
Parameters
List of parameters
1-1044
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
For p9909 = 0, serial numbers and hardware versions are not automatically transferred. In this case, the transfer
must be made using p9904.
Dependency:
Refer to: p9904, p9905
Note:
The modified target topology is automatically saved in a non-volatile fashion when the drive object runs-up (e.g.
after a POWER ON).
Special case for Control Unit and option slot modules:
When replacing these components, independent of p9909, the serial number and hardware version are automati-
cally transferred and saved in a non-volatile fashion.
Description:
Transfer additional inserted DRIVE-CLiQ components into the target topology and add the appropriate drive objects
to the project.
Values:
0:
No selection
1:
Drive object type SERVO
2:
Drive object type VECTOR
3:
SINAMICS GM (DFEMV & VECTORMV)
4:
SINAMICS SM (AFEMV & VECTORMV)
5:
SINAMICS GL (VECTORGL)
Description:
Only for internal Siemens service.
Description:
Only for internal Siemens service.
Description:
Enters the license key for this drive unit.
Example of the license key:
EACZ-QBCA = 69 65 67 90 45 81 66 67 65 dec (ASCII characters)
p9910
Transfer additional components into the target topology / Transfer comp
CU_CX32, CU_S
Can be changed:
C1(1)
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 5
0
p9915
DRIVE-CLiQ data transfer error shutdown threshold master / DLQ fault master
CU_CX32, CU_S
Can be changed:
C1(1)
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
0007 07FF hex
0007 02FF hex
p9916
DRIVE-CLiQ data transfer error shutdown threshold slave / DLQ fault slave
CU_CX32, CU_S
Can be changed:
C1(1)
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
0007 07FF hex
0007 02FF hex
p9920[0...19]
Licensing, enter license key / Enter license key
CU_S
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned8
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...