Parameters
List of parameters
1-644
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
For a 0/1 signal and valid travel direction, when the stop cam is exited, this is detected and the status signal
r2684.14 is set to 0.
Sets message 07492 as alarm (A07492):
For a 0 signal, the axis is stopped with the maximum deceleration (p2573), status signal r2684.14 is set to 1, saved
and the appropriate alarm is output. Only motion away from the STOP cam is permitted.
For a 0/1 signal and valid travel direction, when the stop cam is exited, this is detected and the status signal
r2684.14 is set to 0 and the alarm is deleted.
Description:
Sets the maximum velocity for the function module "basic positioner" (r0108.4).
Dependency:
Refer to: r1084, r1087, p2503, p2504, p2505, p2506
Note:
The maximum velocity is active in all of the operating modes of the basic positioner.
The maximum velocity for the basic positioner should be aligned with the maximum speed/velocity of the
speed/velocity controller:
Rotary encoders:
p2571[1000 LU/min] = min(|r1084|, |r1087|)[1/min] x p2505/p2504 x p2506/1000
Linear encoders:
p2571[1000 LU/min] = min(|r1084|, |r1087|)[m/min] x p2503/10[m]
Description:
Sets the maximum acceleration for the function module "basic positioner" (r0108.4).
Dependency:
Refer to: p2619, p2644
Note:
The maximum acceleration appears to exhibit jumps (without jerk).
"Traversing blocks" operating mode:
The programmed acceleration override (p2619) acts on the maximum acceleration.
"Direct setpoint input/MDI" mode:
The acceleration override is effective (p2644, 4000 hex = 100 %).
"Jog" and "search for reference" modes
No acceleration override is active. The axis starts with the maximum acceleration.
Description:
Sets the maximum deceleration for the function module "basic positioner" (r0108.4).
Dependency:
Refer to: p2620, p2645
p2571
EPOS maximum velocity / v_max
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1 [1000 LU/min]
40000000 [1000 LU/min]
30000 [1000 LU/min]
p2572
EPOS maximum acceleration / a_max
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1 [1000 LU/s²]
2000000 [1000 LU/s²]
100 [1000 LU/s²]
p2573
EPOS maximum deceleration / -a_max
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1 [1000 LU/s²]
2000000 [1000 LU/s²]
100 [1000 LU/s²]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...