List of parameters
Parameters
1-859
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Values:
0:
No sensor available
10:
PTC fault
11:
PTC alarm
12:
PTC alarm and timer stage
20:
KTY84
30:
Bimetallic NC contact fault
31:
Bimetallic NC contact alarm
32:
Bimetallic NC contact alarm and timer stage
Dependency:
Refer to: r0458, p0600, p0601
Note:
Terminals for PTC triplet: X200.5, X200.6
PTC thermistor: Tripping resistance = 1650 Ohm
Description:
Displays the actual temperatures in the motor, measured via an SME 120 or SME 125.
Index:
[0] = SME temperature channel 1
[1] = SME temperature channel 2
[2] = SME temperature channel 3
[3] = SME temperature channel 4
Note:
An invalid temperature is displayed using the value -200°C.
Description:
Sets the component number for the Sensor Module Integrated (SMI) for which data should be saved or down-
loaded.
Dependency:
Refer to: p4691, p4692
Note:
SMI: SINAMICS Sensor Module Integrated
Only component numbers that correspond to a Sensor Module Integrated can be entered.
Description:
Setting to save/download the data for the Sensor Module Integrated (SMI) specified in p4690.
Procedure:
p4690 = set component number
p4691 = 1, 2 set the required procedure (save/download)
p4691 = 0 --> automatically after the procedure has been successfully completed
p4691 = 11, 12, 13, 14, 15 --> error vales if the procedure was not able to be executed
r4620[0...3]
Motor temperatures SME / Mot Temp SME
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
21_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
p4690
SMI component number / SMI comp_no
CU_CX32, CU_S
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 399
0
p4691
Save/download SMI data / Save/DL SMI data
CU_CX32, CU_S
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 15
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...