Parameters
List of parameters
1-150
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Notice:
If p0338 is changed during quick commissioning (p0010 = 1), then the maximum current p0640 is appropriately pre-
assigned. This is not the case when commissioning the motor (p0010 = 3).
Note:
The parameter is automatically preset for motors from the motor list (p0301).
Description:
Displays the rated motor voltage
Note:
For induction motors (p0300 = 1xx) the parameter is set to p0304.
For synchronous motors, parameter r0339 = p0304 is displayed. If p0304 = 0, then r0339 is calculated from p0305
and p0316.
Description:
Setting to reset and automatically calculate filter and control (closed-loop) parameters.
Values:
0:
No calculation
1:
Complete re-calculation. of control parameters with COMM data
2:
Reset control parameters
Notice:
The following parameters are influenced using p0340:
p0340 = 1:
--> All of the parameters influenced for p0340 = 2
--> p3421 = p0223, p0225
--> p3422 = p0227
--> p3424 = p0225
--> p3415, p3425, p3555, p3614, p3620, p3622 are reset to the factory setting dependent on the particular unit.
p0340 = 2:
--> p3560, p3562, p3564, p3603, p3615 and p3617 are reset to the factory setting. For S_INF, these control param-
eters are not available
Note:
When existing the quick commissioning using p3900 > 0, p0340 is automatically set to 1.
At the end of the calculations, p0340 is automatically set to 0.
Description:
Setting to automatically calculate motor parameters and V/f open-loop and closed-loop control parameters from the
rating plate data.
r0339[0...n]
Rated motor voltage / Mot V_rated
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [Vrms]
- [Vrms]
- [Vrms]
p0340
Automatic calculation, control parameters / Calc auto par
A_INF, S_INF
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 2
0
p0340[0...n]
Automatic calculation of motor/control parameters / Calc auto par
SERVO, VECTOR
Can be changed:
C2(3), T
Calculated:
-
Access level:
2
Data type:
Integer16
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 5
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...